CardioPerfect Workstation SpiroPerfect Module – User Manual DIR 80012334 Ver. H 3 / 93 Warranty, Service, and Spare Parts Warranty All repairs on products under warranty must be performed or approved by Welch Allyn. CardioPerfect Workstation. Resting ECG Module - User Manual. DIR 80012333 Ver. Before installing the Resting ECG software. In this chapter, you will find information about the structure of the Welch Allyn CardioPerfect resting ECG software.
- Welch Allyn, Inc. Warrants that the Welch Allyn CardioPerfect Workstation computer based product you have purchased meets the labeled specifications of the Product and will be free from defects in materials and workmanship that occur within 1 year after the date of purchase.
- Welcome to Welch Allyn CardioPerfect Workstation. Welch Allyn CardioPerfect Workstation controls the different diagnostic modules and handles all non-module specific issues, such as patient management and security. You can also use it to search for patients or tests, print tests and import or export tests. This manual is intended as an introduction to Welch Allyn CardioPerfect Workstation and its.
- Welch allyn CARDIOPERFECT Pdf User Manuals. View online or download Welch allyn CARDIOPERFECT User Manual. We have 1 Welch Allyn CARDIOPERFECT manual available for free PDF download: User Manual. WORKSTATION 28. The Welch Allyn CardioPerfect Pocket ECG Window 28. Tools Tab 30. Import Tab 30.
Advertising
4341 State Street Road
Skaneateles Falls, NY 13153 https://renewkwik.weebly.com/2001-dodge-intrepid-manual-download.html.
Skaneateles Falls, NY 13153 https://renewkwik.weebly.com/2001-dodge-intrepid-manual-download.html.
Mat. 711053, Ver. B
CardioPerfect
®
Workstation software installation quick reference
For a detailed installation procedure, including cautions and warnings, insert the CardioPerfect
Workstation software CD, select Browse the manuals folder, and open the installation manual.
Workstation software CD, select Browse the manuals folder, and open the installation manual.
To install the software
Caution: Connect USB devices only after software has been
installed. Otherwise, drivers will have to be installed manually.
installed. Otherwise, drivers will have to be installed manually.
1.
Insert the CardioPerfect Workstation software CD.
The installer menu appears, as shown here.
The installer menu appears, as shown here.
This menu also appears when you open installer.exe
on the CD. The >> symbol indicates the presence of a
submenu.
on the CD. The >> symbol indicates the presence of a
submenu.
2.
Select the desired menu items.
Menu item
Description
Install CardioPerfect
Workstation
Workstation
Select this item to install the CardioPerfect Workstation program and the device drivers (for the ECG recorder and
spirometer) to the hard drive. Follow the instructions on the screen. US users: When prompted, select the
US default settings check box.
spirometer) to the hard drive. Follow the instructions on the screen. US users: When prompted, select the
US default settings check box.
Install Example Data
Select this item if you would like to have some sample data in the database to experiment with.
CardioPerfect Device
Drivers
Drivers
Select this item only if the USB ECG recorder driver or the USB spirometer driver is not working and you want to
reinstall it.
reinstall it.
CardioPerfect
Connectivity Tools
Connectivity Tools
Select this item if you need to install CardioPerfect FileLink
®
, PerfectLink
®
thin client support, or to browse the
Tools folder.
3rd Party Tools and
Service Packs
Service Packs
Select this item if you need to install Adobe Acrobat Reader (so that you can open the user manuals on the CD).
Browse the manuals
folder
folder
Select this item to access the complete set of CardioPerfect user manuals on the CD.
View read me file
Select this item for a description of information contained on the CD.
Advertising
Popular Brands
Popular manuals
Advertising
CardioPerfect Workstation
Resting ECG Module - User Manual
Welch Allyn Workstation Download
Zoom h5 manual download. DIR 80012333 Ver. E
17 / 54
Leadoff, Framing Errors and DCOffset conditions:
If the application detects a Lead-off, DC offset, or Framing error within 10 seconds after you have
started an ECG recording, the recording automatically restarts.
In the case of a Leadoff condition,
the ECG recording will not start until the signal is stabilized. The progress bar of the recording will
remain at 0 until all the signals are of acceptable quality.
You can use the override button to disable the automatic restart.
DCOffSet
remain at 0 until all the signals are of acceptable quality.
You can use the override button to disable the automatic restart.
DCOffSet
The DCOFFSET DETECTED! message displays in the progress bar when
battery power is interrupted or when there is a spike in voltage.
Framing Errors Framing errors display in the progress bar and can occur in CPWS
configurations when the Pro recorder is connected via a serial cable and the
packets of information are delayed.
Leadoff
The Leadoff message displays in the workspace when an electrode is
disconnected. The real-time monitor will displ
![Welch allyn cardioperfect troubleshooting Welch allyn cardioperfect troubleshooting](/uploads/1/3/3/2/133276897/694978949.jpg)
ay “Bad signal on…”. The trace
Welch Allyn Cardioperfect Workstation User Manual Instructions
shows square waves until the signal is stabilized.